Centering Section

The Centering section determines the centering window for bar code scanning.

ScanWedge Entry

Description

Default

Available Values

 

 

Value

 

 

 

 

 

 

 

 

 

CenteringEnable=

Enable and disables the decode

0

0=Disabled; centering is

 

centering window for the decoder.

 

disabled for ScanWedge.

 

 

 

1=Enabled; bar codes are

 

 

 

decoded only if they are

 

 

 

within the centering window

 

 

 

specified by the rest of the

 

 

 

keys in this section.

 

 

 

 

CenteringTop=

Specifies the top coordinate of the

210

Enter the coordinates in pixels.

 

centering window.

 

 

 

 

 

 

CenteringBottom=

Specifies the bottom coordinate of

270

 

 

the centering window.

 

 

 

 

 

 

CenteringLeft=

Specifies the left coordinate of the

346

 

 

centering window.

 

 

 

 

 

 

CenteringRight=

Specifies the right coordinate of

406

 

 

the centering window.

 

 

 

 

 

 

Dolphin® Power Tools User’s Guide

Rev A

5 - 11

 

8/6/08

 

Page 89
Image 89