Table B-3. HP E1429A/B Error Messages (Cont’d)

Code

Message

Description

 

 

 

-161

Invalid block data

The number of bytes in a definite length data block

 

 

does not equal the number of bytes indicated by the

 

 

block header.

 

 

 

-168

Block data not allowed

Block data was specified when another parameter

 

 

type (i.e. discrete, numeric, boolean) is required.

 

 

 

171

Invalid Expression

The expression used to calculate a parameter value

 

 

is invalid.

 

 

 

-178

Expression data not allowed

An expression cannot be used to calculate a

 

 

parameter value .

 

 

 

181

Invalid outside macro definition

A macro parameter placeholder ($<number) was

 

 

encountered outside of a macro definition.

 

 

 

-183

Invalid inside macro definition

A command was encountered that is not allowed

 

 

inside a macro.

 

 

 

184

Macro parameter error

A command inside the macro definition had the wrong

 

 

number or wrong type of parameters.

 

 

 

-211

Trigger ignored

A trigger was received and the digitizer was not in the

 

 

wait-for-trigger state. Or, a trigger was received from

 

 

a source other than the specified source.

 

 

 

-212

Arm ignored

An arm was received and the digitizer was not in the

 

 

wait-for-arm state. Or, an arm was received from a

 

 

source other than the specified source.

 

 

 

-213

Init ignored

INITiate:IMMediate received while the digitizer was

 

 

initiated.

 

 

 

-214

Trigger deadlock

Readings cannot be retrieved using FETCh? or

 

 

READ? because TRIGer:STARt:COUNt INFinite is

 

 

set. Also occurs with READ? and

 

 

TRIGger:STARt:SOURce HOLD or

 

 

TRIGger:STARt:SOURce BUS set.

 

 

 

-215

Arm deadlock

Readings cannot be retrieved using FETCh? or

 

 

READ? because ARM:STARt:COUNt INFinite is set.

 

 

Also occurs with READ? and ARM:STARt:SOURce

 

 

HOLD, ARM:STARt:SOURce BUS, or

 

 

ARM:STARt:SOURce OFF set.

 

 

 

-221

Settings conflict

Refer to the statement appended to the "Settings

 

 

conflict" message for a description of the conflict and

 

 

how it was resolved.

 

 

 

-222

Data out of range

Parameter value is out of range for any digitizer

 

 

configuration.

 

 

 

-224

Illegal parameter value

An exact value, from a list of possible choices, was

 

 

expected.

 

 

 

 

 

 