HP nPartitions (nPars) manual Methodology

Models: nPartitions (nPars)

1 148
Download 148 pages 8.77 Kb
Page 79
Image 79

2.Narrow down the observed issue to the specific troubleshooting procedure required. Isolate the failure to a specific part of the server blade to perform more detailed troubleshooting. For example:

Issue - Front Panel LED blinking

NOTE: The front panel health LED flashes amber with a warning indication, or flashes red with a fault indication.

Look for a system alert on the OA or system console.

Analyze the alert by using the SEL, to identify the last error logged by the server blade. Use the iLO 3 MP commands to view the SEL, through the MP menu interface.

MP MAIN MENU:

CO: Console

VFP: Virtual Front Panel

CM: Command Menu

CL: Console Log

SL: Show Event Logs

HE: Main Help Menu

DB: Debug Shell

X:Exit Connection [ilo3cd92b2fca24] MFG! hpiLO-> sl Event Log Viewer Menu:

Log Name Entries % Full Latest Timestamped Entry

-------------------------------------------------------------------------------

E - System Event 489 18 % 03 Jan 2001 00:11:17

F - Forward Progress 13251 68 % 03 Jan 2001 00:11:17 I - iLO Event 136 27 % 03 Jan 2001 03:30:04

C - Clear All Logs L - Live Events

Enter menu item or [Ctrl-B] to Quit: e

Log Name Entries % Full Latest Timestamped Entry

-------------------------------------------------------------------------------

E - System Event 489 18 % 03 Jan 2001 00:11:17 Event Log Navigation Help:

+ View next block (forward in time, e.g. from 3 to 4)

- View previous block (backward in time, e.g. from 3 to 2) <CR> Continue to the next or previous block

D Dump the entire log F First entry

L Last entry

J Jump to entry number

H View mode configuration - Hex

K View mode configuration - Keyword T View mode configuration - Text

S View mode configuration - Cause/Action A Alert Level Filter options

U Alert Level Unfiltered ? Display this Help menu

Q Quit and return to the Event Log Viewer Menu Ctrl-B Exit command, and return to the MP Main Menu

# Location Alert Encoded Field Data Field Keyword/Timestamp

-------------------------------------------------------------------------------

480 SFW 1,0,2,0 *7 F480003709E1039B 000000000000000F BOOT_HALT_CELL 02 Jan 2001 22:29:12

479 SFW 1,0,2,0 *7 E48000D109E10399 FFFFFF01FFFFFF94 MEM_NO_MEM_FOUND 02 Jan 2001 22:29:12

478 SFW 1,0,2,0 2 40801FB109E10397 0000000000000000 MEM_NON_OPTIMAL_CONFIG 02 Jan 2001 22:29:12

477 SFW 1,0,2,0 *5 BA801F9D09E10395 FFFFFF0100100B74 MEM_DIMM_INFO_HW_DEALLOCATED 02 Jan 2001 22:29:11

476 SFW 1,0,2,0 *5 BA801F9D09E10393 FFFFFF0100090B74 MEM_DIMM_INFO_HW_DEALLOCATED 02 Jan 2001 22:29:11

475 SFW 1,0,2,0 *3 688024FE09E10391 000000000100000F MEM_DDR_TRN_ERR 02 Jan 2001 22:29:11

474 SFW 1,0,2,0 *3 688024FE09E1038F 0000000001010100 MEM_DDR_TRN_ERR 02 Jan 2001 22:29:11

MFG! SL:hpiLO (+,-,<CR>CR>,D,F,L,J,H,K,T,S,A,U,?,Q or Ctrl-B to Quit)->

3.You should have a good idea about which area of the server blade requires further analysis. For example, if the symptom was “server blade will not power-up”, the initial troubleshooting procedure might have indicated a issue with the DC power rail not coming up after the power was turned on.

Methodology 79

Page 79
Image 79
HP nPartitions (nPars) manual Methodology