5 | ILO | 1 | 2 | 4080231200E10008 | 0000000000000000 FW_UPDATE_SUCCESS | ||
|
|
|
|
| 07 | Jan 2010 | 22:40:43 |
4 | ILO | 1 | 2 | 4080236800E10006 | 0000000000000000 FW_UPDATE_SIG_OVERRIDE | ||
|
|
|
|
| 07 | Jan 2010 | 22:33:05 |
3 | ILO | 1 | 2 | 4080230D00E10004 0000000000000000 FW_UPDATE_START | |||
|
|
|
|
| 07 | Jan 2010 | 22:31:23 |
2 | ILO | 1 | 2 | 408022E200E10002 0000000000000000 ENTER_MFG_MODE |
4.Select a, then a threshold filter number to filter events to desired level.
MP:SL
1: Major Forward Progress
2: Informational
3: Warning
5: Critical
7: Fatal
Enter alert level threshold or [Q] to quit filter setup: 3
5.To decode the blinking state of a blade server LED, review the entire SEL and look at events with alert level 2 and above.
Troubleshooting processors
Processor installation order
For a minimally loaded server blade, one processor must be installed in processor slot 0. Install a processor of the same version into processor slot 1 (if purchased). See “ CPU and heatsink module” (page 111) for more information on processor installation.
Processor module behaviors
All physical processors become functional after server power is applied.
Corrected errors anduncorrected errors in any physical processor core can cause a local MCA event, which can have one of the following consequences:
•Can cause the entire system to crash.
•The failure is corrected and the processor is restarted.
•The failure is corrected, but the processor which experiences excessive correctable errors is marked for deconfiguration.
Enclosure information
This installation document covers only the BLC860C i4 , BLC 870C i4 and BLC 890Ci 4 server blades, and does not include any specific server blade enclosure information. For server blade enclosure information, go to:
Cooling subsystem
The server blade does not contain any fans. Cooling is handled by the enclosure.
Firmware
The server blade has two sets of firmware installed:
•Server blade firmware
•iLO 3 MP firmware
96 Troubleshooting