8.Align the DIMM's notch with the slot's notch.

CAUTION: Use only HP low profile DIMMs. DIMMs from other sources might adversely affect data integrity.

DIMMs do not seat fully if turned the wrong way.

DIMMs in a pair or quad must be identical.

9.Insert a DIMM in a slot and push down firmly until the latches click shut, first one latch and then the other.

IMPORTANT: To ensure proper function of the memory baffle, all DIMM latched must be in the CLOSED position.

Mezzanine cards

Optional mezzanine cards enable additional network connectivity and provide Fibre Channel support. For mezzanine card locations, see “Server blade components” (page 8).

Optional mezzanine cards are classified as Type I mezzanine cards and Type II mezzanine cards. The card type determines where it can be installed in the server blade:

Install Type I mezzanine cards on any mezzanine connector.

Install Type II mezzanine cards only on Mezzanine 2 connector or Mezzanine 3 connector. To install a card:

1.Power off the server blade and remove it from the server blade enclosure (“Preparing the server blade for servicing”).

2.Remove the access panel (“Removing the access panel” (page 38)).

3.Remove the mezzanine connector cover.

Installing internal components 49

Page 49
Image 49