HP nPartitions (nPars) manual Sysset

Models: nPartitions (nPars)

1 148
Download 148 pages 8.77 Kb
Page 65
Image 65

NOTE: This is just an example so actual version numbers may be different from what is shown.

If an update is required, it may need to be completed using the HPSUM Force Install option for both the iLO 3 and system firmware bundles. HPSUM should detect the mismatch and set the Force Install option by default. When finished, log back into the iLO 3 MP of the Monarch blade and enter sr from the Command Menu to verify that the firmware levels on all conjoined blades are now consistent and up to date.

12.Exchange the System Information Parameters by following the steps below. For more information regarding the information contained in the System Information Parameters, see “Blade link and system information parameters” (page 70).

a.Log into the Monarch iLO 3 MP, enter the Command Menu, and execute the command sysset. This will list the system information parameters stored in the Upgrade Blade Link (primary) and those stored on the server blade (secondary). Below is an example of the output when upgrading from a BL860c i4 to a BL870c i4.

[ilo002264fee1be] CM:hpiLO-> sysset

SYSSET

Current System Information Parameters:

Manufacturer

: HP

Product Name (prodname)

: Integrity BL870c i2

Secondary Product Name

: Integrity BL860c i2

Product Number (prodnum)

: AM358A

Secondary Product Number

: AD399A

Serial number (serial)

: Uninitialized

Secondary Serial Number

: USA0003

UUID (uuid)

: FFFFFFFF-FFFF-FFFF-FFFF-FFFFFFFFFFFF

Secondary UUID

: 89742B3C-AD78-11DF-BB2A-5ABBD7A51B74

Product ID

: 0x702

An Upgrade Blade Link has been detected.

Primary and secondary system parameters values do not match. Copy secondary UUID and serial number to primary? (Y/[N]):

The product name and product number from the Upgrade Blade Link reflect a BL870c i4, while the Secondary product name and number (from the Monarch Server) reflect the original BL860c i4.

b.The system detects the Upgrade Blade Link and prompts you to make the required system information exchanges between Upgrade Blade Link and the server. Enter y to approve the exchange. You will then be informed that a reset of the iLO 3 MP is necessary for the changes to take effect.

Copy secondary UUID and serial number to primary? (Y/[N]): y

-> Secondary system parameters values have been copied to primary system parameters.

->System Information parameters have been updated.

iLO MP needs to be reset in order for these changes to take effect

c.Reset the iLO 3 MP by entering xd –r–ncat the Command Menu prompt.

[ilo002264fee1be] CM:hpiLO-> xd -r -nc XD -r -nc

-> MP reset requested MP is now being reset...

Installing internal components 65

Page 65
Image 65
HP nPartitions (nPars) manual Sysset