HP nPartitions (nPars) RAID configuration and other utilities, Using the saupdate command, Syntax

Models: nPartitions (nPars)

1 148
Download 148 pages 8.77 Kb
Page 125
Image 125

A RAID configuration and other utilities

Configuring a Smart Array Controller

Using the saupdate command

The saupdate command is used to query or change the mode of the Smart Array P410i and Smart Array P411 controllers to HBA or RAID. Querying or changing modes is not supported for other controllers.

The following are the newly added commands to saupdate:

get_mode

set_mode

get_mode

This command displays the current mode of the controllers.

NOTE: Terminal windows should be set to a window size of 80 columns x 25 rows for optimal viewing of the console at UEFI.

Syntax

saupdate get_mode <controller>

<controller> can be any one of the strings listed in Table 14.

Table 14 <controller> strings

<controller>

Meaning

<seg:bus:dev:func>

A controller having the PCI segment id, bus id, device id

 

and function id is addressed

all

Addresses all controllers in the system

<model>

Controllers of a particular type indicated by the <model>

 

string are addressed

Configuring a Smart Array Controller 125

Page 125
Image 125
HP nPartitions (nPars) manual RAID configuration and other utilities, Configuring a Smart Array Controller, Syntax