2 Site preparation

The HP Integrity BL860c i4 Server Blade does not have cooling or power systems. Cooling and power is provided by the c-Class enclosure.

IMPORTANT: To avoid hardware damage, allow the thermal mass of the product to equalize to the temperature and humidity of the installation facility after removing the shipping materials. A minimum of one hour per 10°C (50°F) of temperature difference between the shipping facility and installation facility is required

Server blade dimensions and weight

Table 1 Server blade dimensions and weight for the BL860c i4

Dimensions

value

Height

36.63 cm (14.42 in.)

Width

5.14 cm (2.025 in.)

Depth

48.51 cm (19.1 in.)

Weight

Unloaded: 8.6 kg (19 lb)

 

Fully loaded: 11.3 kg (25 lb)

Table 2 Blade Link dimensions and weight

Blade Link type

Height

Width

Weight

BL1 (BL860 i4)

44 mm (1.73 in)

51 mm (2 in)

.5 lb (.22 kg)

BL2 (BL870 i4)

44 mm (1.73 in)

106 mm (4.17 in)

1 lb (.45 kg)

BL4 (BL890 i4)

44 mm (1.73 in)

212 mm (8.34 in)

2 lb (.90 kg)

Enclosure information

All three blade configurations are supported in HP c7000 and c3000 Enclosures. For more enclosure information see: http://h71028.www7.hp.com/enterprise/cache/316735-0-0-0-121.htm.

Enclosure environmental specifications

NOTE: This information is for both c3000 and c7000 Enclosures.

Specification

Value

Temperature range 1

 

Operating

10°C to 35°C (50°F to 95°F)

Non-operating

-30°C to 60°C (-22°F to 140°F)

Wet bulb temperature

 

Operating

28ºC (82.4ºF)

Non-operating

38.7ºC (101.7ºF)

Relative humidity (noncondensing)2

 

Server blade dimensions and weight