Table 2. Critical remote alerts
Alphanumeric | Alphanumeric |
|
|
pager code | recovery code | Event | Action |
|
|
|
|
00 | 50 | Temperature | Generates an alert if any of the monitored temperatures are |
|
| irregularity | outside critical threshold values. To view the threshold |
|
|
| values, click the temperature readings on the System Health |
|
|
| page. If a critical temperature condition is detected, the |
|
|
| server shuts down and turns off, regardless of the alert |
|
|
| notification setting. |
|
|
|
|
01 | 51 | Voltage | Generates an alert if the voltages of any of the monitored |
|
| irregularity | power supplies fall outside their specified operational ranges. |
|
|
| To view the operational ranges, click the voltage readings on |
|
|
| the System Health page. If a critical voltage condition is |
|
|
| detected, the server shuts down and turns off, regardless of |
|
|
| the alert notification setting. |
|
|
|
|
02 | 52 | Tampering | Generates an alert if physical intrusion of the server is |
|
|
| detected. Tamper monitoring is not available on some |
|
|
| servers, in which case this setting is ignored. |
|
|
|
|
03 | 53 | Multiple fan | Generates an alert if two or more of the cooling fans in the |
|
| failure | server fail. |
|
|
|
|
04 | 54 | Power failure | Generates an alert if any of the server power supplies fail. |
|
|
|
|
05 | 55 | Hard disk drive | Generates an alert if one or more of the hard disk drives in |
|
| failure | the server fail. |
|
|
|
|
06 | 56 | VRM failure | Generates an alert if one or more voltage regulator modules |
|
|
| (VRMs) fail. This setting is ignored for servers without VRMs. |
|
|
|
|
|
| Reserved for future use. | |
|
|
|
|
| Warning alerts |
| |
|
| Warning alerts are generated for events that might progress to a critical | |
|
| level. If the Select all warning alerts check box is selected, an alert | |
|
| can be sent for any warning alert. | |
Table 3. Warning remote alerts |
|
| |
|
|
|
|
Alphanumeric | Alphanumeric |
|
|
pager code | recovery code | Event | Action |
|
|
|
|
10 | 60 | Redundant power | Generates an alert if a redundant power supply fails. |
|
| supply failure |
|
|
|
|
|
11 | 61 | Single fan failure | Generates an alert if one fan fails. |
|
|
|
|
12 | 62 | Temperature | Generates an alert if any monitored temperatures are |
|
| irregularity | outside the warning threshold values. To access these |
|
|
| temperature threshold values, click the temperature |
|
|
| readings on the System Health page. Unlike the critical |
|
|
| temperature event, this event will not initiate a server |
|
|
| shutdown. |
|
|
|
|
13 | 63 | Voltage | Generates an alert if any monitored voltages are outside the |
|
| irregularity | warning threshold values. To access these voltage range |
|
|
| values, click the voltage readings on the System Health |
|
|
| page. Unlike the critical voltage event, this event will not |
|
|
| initiate an automatic server shutdown. |
|
|
|
|
14 - 19 |
|
| Reserved for future use. |
|
|
|
|
28 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User’s Guide