Table 2. Critical remote alerts

Alphanumeric

Alphanumeric

 

 

pager code

recovery code

Event

Action

 

 

 

 

00

50

Temperature

Generates an alert if any of the monitored temperatures are

 

 

irregularity

outside critical threshold values. To view the threshold

 

 

 

values, click the temperature readings on the System Health

 

 

 

page. If a critical temperature condition is detected, the

 

 

 

server shuts down and turns off, regardless of the alert

 

 

 

notification setting.

 

 

 

 

01

51

Voltage

Generates an alert if the voltages of any of the monitored

 

 

irregularity

power supplies fall outside their specified operational ranges.

 

 

 

To view the operational ranges, click the voltage readings on

 

 

 

the System Health page. If a critical voltage condition is

 

 

 

detected, the server shuts down and turns off, regardless of

 

 

 

the alert notification setting.

 

 

 

 

02

52

Tampering

Generates an alert if physical intrusion of the server is

 

 

 

detected. Tamper monitoring is not available on some

 

 

 

servers, in which case this setting is ignored.

 

 

 

 

03

53

Multiple fan

Generates an alert if two or more of the cooling fans in the

 

 

failure

server fail.

 

 

 

 

04

54

Power failure

Generates an alert if any of the server power supplies fail.

 

 

 

 

05

55

Hard disk drive

Generates an alert if one or more of the hard disk drives in

 

 

failure

the server fail.

 

 

 

 

06

56

VRM failure

Generates an alert if one or more voltage regulator modules

 

 

 

(VRMs) fail. This setting is ignored for servers without VRMs.

 

 

 

 

07-09

 

 

Reserved for future use.

 

 

 

 

 

Warning alerts

 

 

 

Warning alerts are generated for events that might progress to a critical

 

 

level. If the Select all warning alerts check box is selected, an alert

 

 

can be sent for any warning alert.

Table 3. Warning remote alerts

 

 

 

 

 

 

Alphanumeric

Alphanumeric

 

 

pager code

recovery code

Event

Action

 

 

 

 

10

60

Redundant power

Generates an alert if a redundant power supply fails.

 

 

supply failure

 

 

 

 

 

11

61

Single fan failure

Generates an alert if one fan fails.

 

 

 

 

12

62

Temperature

Generates an alert if any monitored temperatures are

 

 

irregularity

outside the warning threshold values. To access these

 

 

 

temperature threshold values, click the temperature

 

 

 

readings on the System Health page. Unlike the critical

 

 

 

temperature event, this event will not initiate a server

 

 

 

shutdown.

 

 

 

 

13

63

Voltage

Generates an alert if any monitored voltages are outside the

 

 

irregularity

warning threshold values. To access these voltage range

 

 

 

values, click the voltage readings on the System Health

 

 

 

page. Unlike the critical voltage event, this event will not

 

 

 

initiate an automatic server shutdown.

 

 

 

 

14 - 19

 

 

Reserved for future use.

 

 

 

 

28 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User’s Guide

Page 36
Image 36
IBM Remote Supervisor Adapter II Can be sent for any warning alert, Alphanumeric Pager code Recovery code Event Action