1.Log in to the Remote Supervisor Adapter II where you want to set local events. For more information, see Chapter 2, “Opening and using the Web interface,” on page 5.

2.In the navigation pane, click Alerts and scroll down to the Monitored Local Events area.

3.Select the events that you want to store in the event log. The Remote Supervisor Adapter II stores the notification only in the event log.

Local events are generated for events that are sent to IBM Director, if it is installed, on the server where the ASM subsystem is located. These events are not sent to remote alert recipients. If the Select all local events check box is selected, an alert can be sent for any local event.

Table 5. Local events

Event

Action

 

 

Event log 75% full

Generates a local notification if the event log reaches 75% of

 

capacity.

 

 

Voltage irregularity

Generates a local notification if any of the monitored voltages

 

exceed their thresholds.

 

 

Power off

Generates a local notification if the server is turned off.

 

 

Power supply failure

Generates a local notification if a power-supply failure is

 

detected.

 

 

Event log full

Generates a local notification if the event log reaches its

 

capacity. At capacity, the oldest events are deleted.

 

 

Redundant power supply

Generates a local notification if the redundant power supply

failure

fails.

 

 

Tampering

v Generates a local notification if the server cover is removed.

 

This feature is available only on some servers.

 

v Generates a local notification if there are five login failures

 

(refresh 2 or later firmware only).

 

 

DASD failure

Generates a local notification if any hard disk drive failures are

 

detected.

 

 

Remote login

Generates a local notification if a remote login occurs.

 

 

Temperature irregularity

Generates a local notification if any of the monitored

 

temperatures exceed thresholds.

 

 

Fan failure

Generates a local notification if one or more cooling fans fail.

 

 

PFA notification

Generates a local notification if any of the hardware in the

 

server generates a PFA event.

 

 

Partition configuration

Generates a local notification if any of the hardware in the

 

server generates a partition configuration event.

 

 

4. Scroll to the bottom of the page and click Save.

Configuring the serial connectors

Note: This feature is not available for the Remote Supervisor Adapter II SlimLine on some server models.

To configure the serial connector, complete the following steps:

1.Log in to the Remote Supervisor Adapter II on which you want to configure the serial port. For more information, see Chapter 2, “Opening and using the Web interface,” on page 5.

30 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User’s Guide