1.Log in to the Remote Supervisor Adapter II where you want to set local events. For more information, see Chapter 2, “Opening and using the Web interface,” on page 5.
2.In the navigation pane, click Alerts and scroll down to the Monitored Local Events area.
3.Select the events that you want to store in the event log. The Remote Supervisor Adapter II stores the notification only in the event log.
Local events are generated for events that are sent to IBM Director, if it is installed, on the server where the ASM subsystem is located. These events are not sent to remote alert recipients. If the Select all local events check box is selected, an alert can be sent for any local event.
Table 5. Local events
Event | Action |
|
|
Event log 75% full | Generates a local notification if the event log reaches 75% of |
| capacity. |
|
|
Voltage irregularity | Generates a local notification if any of the monitored voltages |
| exceed their thresholds. |
|
|
Power off | Generates a local notification if the server is turned off. |
|
|
Power supply failure | Generates a local notification if a |
| detected. |
|
|
Event log full | Generates a local notification if the event log reaches its |
| capacity. At capacity, the oldest events are deleted. |
|
|
Redundant power supply | Generates a local notification if the redundant power supply |
failure | fails. |
|
|
Tampering | v Generates a local notification if the server cover is removed. |
| This feature is available only on some servers. |
| v Generates a local notification if there are five login failures |
| (refresh 2 or later firmware only). |
|
|
DASD failure | Generates a local notification if any hard disk drive failures are |
| detected. |
|
|
Remote login | Generates a local notification if a remote login occurs. |
|
|
Temperature irregularity | Generates a local notification if any of the monitored |
| temperatures exceed thresholds. |
|
|
Fan failure | Generates a local notification if one or more cooling fans fail. |
|
|
PFA notification | Generates a local notification if any of the hardware in the |
| server generates a PFA event. |
|
|
Partition configuration | Generates a local notification if any of the hardware in the |
| server generates a partition configuration event. |
|
|
4. Scroll to the bottom of the page and click Save.
Configuring the serial connectors
Note: This feature is not available for the Remote Supervisor Adapter II SlimLine on some server models.
To configure the serial connector, complete the following steps:
1.Log in to the Remote Supervisor Adapter II on which you want to configure the serial port. For more information, see Chapter 2, “Opening and using the Web interface,” on page 5.
30 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User’s Guide