System alerts
System alerts are generated for events that occur as a result of system errors. If the Select all system alerts check box is selected, an alert can be sent for any system alert.
Notes:
a.The Select all system alerts check box is not available on all servers.
b.Hard disk drive Predictive Failure Analysis (PFA) alerts are not monitored.
Table 4. System remote alerts
Alphanumeric | Alphanumeric |
|
|
pager code | recovery code | Event | Action |
|
|
|
|
20 | 70 | POST timeout | Generates an alert if an enabled POST timeout value is |
|
|
| exceeded. The POST timeout value is configured in the |
|
|
| Server Timeouts area on the System page. |
|
|
|
|
21 | 71 | O/S timeout | Generates an alert if an enabled operating system timeout |
|
|
| value is exceeded. The operating system timeout value is |
|
|
| configured in the Server Timeouts area on the System |
|
|
| page. The O/S timeout alert must be checked to enable |
|
|
| remote |
|
|
|
|
22 | 72 | Test alert | Generates an alert if the Generate Test Alert button is |
|
|
| clicked on the Remote Alert Recipients page. |
|
|
|
|
23 | 73 | Power off | Generates an alert if the server is turned off. |
|
|
|
|
24 | 74 | Power on | Generates an alert if the server is turned on. |
|
|
|
|
25 | 75 | Boot failure | Generates an alert if an error occurs that prevents the |
|
|
| server from starting. |
|
|
|
|
26 | 76 | Loader timeout | Generates an alert if an enabled server loader timeout value |
|
|
| is exceeded. The system loader timeout value is configured |
|
|
| in the Server Timeouts area on the System page. |
|
|
|
|
27 | 77 | PFA notification | Generates an alert if a PFA notification is generated by the |
|
|
| server hardware. This feature is available only on servers |
|
|
| that have |
|
|
|
|
28 - 29 |
|
| Reserved for future use. |
|
|
|
|
38 | 88 | Partition | Generates an alert if a partition configuration notification is |
|
| configuration | generated by the server. This feature is available only on |
|
|
| servers that have partitionable hardware. |
|
|
|
|
39 | 89 | Event log | Generates an alert if the event log reaches 75% or 100% of |
|
|
| capacity, or if the log is cleared (Refresh 2 or later firmware |
|
|
| only). |
|
|
|
|
4. Scroll to the bottom of the page and click Save.
Setting local events
Note: For the Remote Supervisor Adapter II SlimLine, the setting local events feature is available only when using
Complete the following steps to select the local events to which the Remote
Supervisor Adapter II will respond: