Appendix C - Using Non-IDC Motors with the Impulse
C-4
Anti -Resonance
Damping Gain 1 - Enter the recommended value.
Damping Gain 2 - If a value is present you may leave it as
is or enter a value according to the table:
Note: Both Damping Gains (1 and 2) must be configured.
Click OK and you will return to the Motor Editor.
Click OK or Save in the Motor Editor window. You will be prompted to overwrite an exist-
ing file.
Damping Gain 2
Motor Frame Size Enter This Value
17 6.0
23 4.0
34 2.0