Chapter 5 - Configuring Impulse with an IDC Keypad

Renaming an Open Project File

This option allows you to rename (or name) the currently-open project file. Project file names are entered using a combination of the ALPHA and numeric keys. Project file names consist of numeric digits and alphabet letters and are limited to 10 characters. Alphabet characters are accessed by pressing the ALPHA key and repeatedly pressing the numeric key until the desired letter is displayed on the screen. Use the right and left arrow keys to move the cursor.

If RENAME is selected and a project file is not open, an error message will be displayed.

EDIT

> FILE > RENAME

 

Requires Open File

OK

Using the SETUP Sub-Menus for Configuring Your System

The following table shows the structure within the EDIT > SETUP sub-menu. For more detailed descriptions of setup parameters, see Chapter 5 - Configuring Impulse with the FP100 or FP220 Keypad.

Sub-Menu

Setup Parameter

Description of Setup Parameter

COMMAND

Direction

Positive or negative motor direction

 

Shutdown

Active Low or Active High polarity

 

 

 

 

Drive Resolution

Operating step resolution

 

 

 

 

Stop Rate

Deceleration rate

 

 

 

 

Jog

Acceleration/Deceleration, and High/Low Jog speeds

 

 

 

MOTOR

Probe the Motor

Probes for motor characteristics and sends 1 kHz tone

 

Motor Type

IDC motor type

 

 

 

 

Motor Current

Operating current

 

 

 

MECHANICS

User Units

Choose inches or millimeters, or toggle between revolutions

 

 

and steps

 

Units Gear Ratio

Units scaling ratio for distance, velocity, and acceleration

 

 

 

TUNING

X-SM1, X-SM2, X-SM3

Empirical fine tuning of the X-Smoothness

 

 

 

ADVANCED

Anti-Resonance

Anti-resonance gain settings

 

Profiling

Enabling Multi-Stepping and Dynamic Smoothing

 

 

 

 

Stop Reduction Timeout

Set the stop mode current reduction timeout period

 

 

 

 

Idle Mode Reduction

Set the idle mode current reduction timeout period

 

 

 

 

Stall Detection

Enables Open Loop Stall Detect

 

 

 

I/O

Input

Configure 4 inputs

 

Output

Configure 1 output

 

 

 

 

Polarity

Select Active High or Active Low polarity

 

 

 