Chapter 4 - Configuring Impulse with Application Developer

Output Descriptions

Brake: The Brake output is activated on any fault condition. This provides a control signal to engage a brake when the Impulse loses torque due to a fault. The Brake output also provides a polarity-configurable fault output since the dedicated fault output is fixed as an active high, sinking output. Note: The Brake output is not intended nor designed as a power source for a mechanical brake.

In Motion: The In Motion output is activated upon receiving incoming step pulses or when a stored move (Motion Node option) is running. The minimum step frequency that the internal velocity tachometer can render is 156.25 Hz (156.25 / Step Resolution in RPS). Input step frequencies below 156.25 Hz will not activate the In Motion output.

Stall: The Stall output is activated when OLSD™ (Open Loop Stall Detect) detects a motor stall.

4-20

Page 44
Image 44
Impulse PCW-5181 user manual Output Descriptions