Chapter 4 - Configuring Impulse with Application Developer
4-14
Jog High (Jog High Speed) - Defaul t = 2.00 (user-defined units )
Numeric Precision
Select Standard to limit the decimal precision of accelerations, decelerations, velocities,
and distances to the following:
Accels and Decels: #.x (One decimal place)
Velocities: #.xx (Two decimal places)
Distances: #.xxx (Three decimal places)
The Standard decimal precision is sufficient for most applications. Standard is the d efau lt
setting.
Note: The keypad (FP100 or FP220) only supports Standard decimal precision, therefore
project files intended to be used in conjunction with the keypad must be created using the
Standard setting. Attempting to load a project file into the keypad without Standard
decimal precision will result in an error.
Select Extended to limit the decimal precision of accelerations, decelerations, velocities
and distances to the following:
Accels and Decels: #.xxx (Three decimal places)
Velocities: #.xxxxx (Five decimal places)
Distances: #.xxxxx (Five decimal places)
Project files created with Extended decimal precision may be edited only in Application
Developer.