Chapter 6 - Hardware Reference

Remote Mounting Your Keypad

The keypad can easily be mounted and sealed to NEMA 4 specifications by using the included mounting gasket and 6-foot communication cable. Warning: Do not attach the gasket to the keypad. Attach the gasket with the adhesive side toward the mounting enclosure. A pressure-seal is formed between the gasket and the keypad, while the adhesive maintains the seal between the enclosure and the gasket.

A Keypad Mounting Template is included with every keypad, and a not to scale mounting dimensions drawing can be found on the next page for reference. Please pay particular attention to the CAUTION on the template.

Warning

1)When mounting the keypad on wall-type surfaces (as shown in the illustration below) be absolutely certain that you have accurately estimated the proper length of mounting screws. Your keypad may be damaged if a mounting screw is allowed to extend more than 0.20 inches into the keypad.

2)When mounting the keypad to a metal surface, it is highly advisable that the keypad be insulated from the metal surface by using non-conductive fasteners (screws, washers, etc.).

End View of Wall-Mounted Keypad with Cover Removed

Mounting Screw

The circuit board may be damaged if any mount- ing screw is allowed to extend more than 0.20’’ into the keypad.

mounting surface

keypad gasket

Keypad

Circuit Board

Extending the Cable Length to Your Keypad

The keypad cable may be extended if necessary, but at longer distances your keypad may require a separate, regulated 5 VDC (500mA) power supply as shown in the illustration below. Consult IDC Applications Engineering if you have questions about this procedure.

 

N/C GND RX TX +5V

 

+5V

GND

RX

TX

+5V

COM

 

SHLD

+5V Regulated

COM

Power Supply

PORT

 

KEYPAD