Chapter 4 - Configuri ng Imp uls e wi th Appl ic atio n Deve lop er
4-3

Upload Project

1. Begin by clicking the Upload Project button on the
Application Developer Startup window. You will see the
Control Type Selection menu (shown right).
2. Configuration begins by selecting your Impulse from the
list of Steppers. Click OK.
3. Select the Port you will use to connect the Impulse.
4. Select the Unit Number (from 1 - 99) of the Impulse being configured.
5. To test comm unication usi ng th e curren t setup, click on Test Connection. Click OK.
6. Skip the section on Using the Project Wiz ard and go to Fine Tuning Your Application.
Note: Echo and Mode are not available; they have no effect on the Impulse drive.
Comm Port Settings
(for reference only)
RS-232C/RS-485
Baud Rate 19200 (fixed)
Stop Bits 1
Data Bits 8
Parity None
XON/XOFF Yes