Chapter 5 - Configuring Impulse with an IDC Keypad

4.Press ESC.

5.Press YES (F1) to save the new settings, or press NO (F3) to restore the original settings.

Keep New Settings?

YESNO

Configure X-SM2 and X-SM3 using the same procedures as X-SM1 (i.e. VALUE, TEST SPEED, and FINE).

ADVANCED SETUP

The following parameters must be configured in the ADVANCED SETUP sub-menu:

ANTI-RESONANCE (A-RES)

STOP RED TIMEOUT (I-STOP)

 

GAIN 1

 

IDLE MODE REDUCTION (I-IDLE)

 

GAIN 2

 

 

 

TIMEOUT

 

Profiling (PRFILE)

 

%RED

 

MULTI (Multistepping)

STALL DETECTION (STALL)

 

DYNSM (Dynamic Smoothing)

 

DISABLED

 

DSGAIN (Dynamic Smoothing Gain)

 

ENABLED

 

 

 

 

 

 

 

 

 

EDIT

> SETUP > ADVNCE >

 

-ADVANCED SETUP -

 

 

 

A-RES DYN-SM I-STOP

 

 

 

 

 

 

 

 

 

 

 

 

 

-ADVANCED SETUP -

 

 

 

 

I-IDLE STALL

 

Configuring Anti-Resonance Gain

EDIT

> SETUP > ADVNCE > A-RES

 

- - ANTI-RESONANCE - - GAIN1 GAIN2

GAIN 1

This option allows you to configure the anti-resonance gain (#1) between 0 and 32,767. Setting gain at 0 disables the anti-resonance feature, regardless of the GAIN2 setting.

1.Press GAIN1 (F1).

2.Using numeric keys, enter a gain of between 0 and 32,767.

3.Press ESC.

- Anti-Res Gain #1 -

0

GAIN2 (required only if GAIN1 was configured)

This option allows you to configure the anti-resonance gain (#2) between 0.1and 25.0.

1.Press GAIN2 (F2).

2.Using numeric keys, enter a gain of between 0.1 and 25.0.

3.Press ESC.

- Anti-Res Gain #2 -

0

5-17

Page 69
Image 69
Impulse PCW-5181 user manual Configuring Anti-Resonance Gain