Chapter 5 - Configuring Impulse with an IDC Keypad
5-17
4. Press ESC.
5. P ress YES (F1) t o save the n ew set tings, o r pr ess NO (F 3) to
restore the original settings.
Configure X-SM2 and X-SM3 using the same procedures as X-SM1 (i.e. VALUE, TEST SPEED,
and FINE).

ADVANCED SETUP

The foll owing par ameters must be co nfigured in the ADVANC ED SETUP sub-menu:

Configuring Anti -Resonance Gain

GAIN 1
This option allows you to configure the anti-resonance gain (#1) between 0 and 32,767. Setting gain
at 0 disables the anti-resonance feature, regardless of the GAIN2 setting.
1. Press GAIN1 (F1).
2. Using numeric keys, enter a gain of between 0 and 32,767.
3. Press ESC.
GAIN2 (required only if GAIN1 was configured)
This option allow s you to configure the anti-resona nce g ain (#2) between 0.1an d 25.0.
1. Press GAIN2 (F2).
2. Using numeric keys, enter a gain of between 0.1 and 25.0.
3. Press ESC.
Keep New Settings?
YES NO
ANTI-RESONANCE (A-RES)
GAIN 1
GAIN 2
Profiling (PRFILE)
MULT I (M ultis tep pin g)
DYNSM (Dynamic Smoo thing)
DSGAIN (Dynamic Smoothing Gain)
STOP RED TIMEOUT (I-STOP)
IDLE MODE REDUCTION (I-IDLE)
TIMEOUT
%RED
STA LL DETECTION (STALL)
DISABLED
ENABLED

> SETUP > ADVNCE >

EDIT
-
ADVANCED SETUP
-
A-RES DYN-SM I-STOP
-
ADVANC ED SETU P
-
I-IDLE STALL

> SETUP > ADVNCE > A-RES

EDIT
- - ANTI-RESONANCE - -
GAIN1 GAIN2
- Anti-Res Gain #1
-
0
- Anti-Res Gain #2
-
0