Chapter 3 - Connecting and Installing Your Impulse

C. Connecting an IDC Keypad

Two versions of IDC keypads can be used with the Impulse drive. The FP100 works only with the Impulse, while the FP220 can be used with the Impulse as well as IDC’s Smart Drives (see keypad-specific information below).

The COM PORT on the front panel of the Impulse is used for connecting either version of keypad.

Power is applied to either version of keypad when power is connected to the Impulse.

COM

COM

PORT

PORT

 

 

I/O

Keypad with Impulse RS232C

Using a Keypad with Impulse RS232C

FP100 Keypad

Connect the FP100 Keypad to the Impulse with the cable supplied with the keypad.

FP220 Keypad (Version 3.0 or higher)

Only FP220 Keypad versions 3.0 and higher will work with the Impulse drive.

To use an FP220 keypad with your Impulse, you must set DIP-switch #3 to the ON position and switch #s 1, 2, and 4 to OFF.

The FP220 uses the same keypad cable as the FP100.

Keypad

Using a Keypad with Impulse RS485

Impulse RS485 requires either the FP100-RS485 or FP220-RS485 keypad.

On the FP220-RS485 keypad only, set DIP switches as described above. Both FP100-RS485 and FP220- RS485 keypad are connected as follows:

1.Connect the keypad cable to the keypad and to the Impulse.

2.Connect the keypad power supply cable to the keypad as shown in the illustration.

3.Plug in the AC adapter.

Keypad with Impulse RS485

Keypad

3

2

1

3-7

Page 17
Image 17
Impulse PCW-5181 Connecting an IDC Keypad, Using a Keypad with Impulse RS232C, Using a Keypad with Impulse RS485