Kodak 20P manual Using the System, a.Click OK The following list of options appears

Models: 20P

1 198
Download 198 pages 51.29 Kb
Page 28
Image 28
a.Click OK.

Using the System

If the print densities are out of tolerance, a graph appears, allowing you to select the type of data and planes that you want to see displayed.

a.Click OK.

The following list of options appears.

Re-read the densitometer values is the most useful when the graphs show an unusual plot. Rereading the test print lets you validate the graph, then returns you to the Out of Tolerance dialog box.

Iterate again using a newly calculated calibration LUT allows you to keep printing test prints with the newly created LUT without having to save the LUT table.

Calculate and download a printing LUT and stop: When you select this option, the file is saved and given the same creation date and time as the name.

Cancel and return the printer to its original state saves nothing. Any corrupted data created after you saved the last time is thrown away.

2-8

September 2000

Page 28
Image 28
Kodak 20P manual Using the System, a.Click OK The following list of options appears