DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures
Page10-422DIG-BD (Digital Line Circuit Pack)
10
DIG-BD (Digital Line Circuit Pa c k)
Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation for
circuit pack level errors. See also DIG-LINE (Digital Line) Maintenance
documentation for related line information.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); a nd SS is t he address of the sl ot in the car rier
where the circuit pack is located (for example, 01, 02, ..., etc.).
MO Name (in
Alarm Log) Alarm
Level Initial Command to Run1Full Name of MO
DIG-BD MIN test board PCSS sh Digital Line Circuit Pack
DIG-BD WRN test board PCSS sh Digital Line Circuit Pack