DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids

Page8-400test trunk

8
Output
The responses display on a test-by-test basis with one line of data for each test result. The following screen is an example of the output for the test trunk 78
command.
1. If no alarms are registered against the maintenance object then the test sequence exe rcises once. The

long clear

option forces a clear of all a larms i f no erro rs are enco unte red d uring test ing. T he
short clear
option only clears alarms
pertinent to tests in the short sequence.
2. Refer to the Report Schedu ler and System Printer feature sp ecification for more details.
Action/
Object Qualifier Qualifier Descriptio n Permissions Defaults Feature
Interactions
test trunk

group

number

member

number
short
long

repeat

number
clear
schedule
Administered group number (1-99)
Administered number iden tifying a
particular trunk within a tru nk group (1-99).
Command executes a series of
nondestructive diagnostic tests.
Command executes a more
comprehensive and longer ver s io n of t he
both destructive and nonde structive
diagnostic tests.
How many times each test in the sequence
is repeated (1-100)
This option causes the test sequenc e (sh ort
or long) to repeat until the alarm (if any) is
cleared or a single test in the sequence
fails.1
Command is validated and the n a
scheduling form displays to sc hedule
execution of the command. The command
is then placed in the comma nd queue and
is executed at the specifi ed time. The
information displayed by the command is
sent to the system printer in stead of the
screen.2
Examples:
test trunk 78 l
test trunk 80/1 sh r 2
test trunk 78/2 l r 25
test trunk 78/2 l r 25 schedule
test trunk 80
test trunk 80 schedule
test trunk 78 r 4
test trunk 78 c
init
inads
craft
cust
Test Seq.
= short;
Repeat = 1
none