DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-1054PR-MAINT (Maintenance Processor)

10
MTP Outpulse Relay Test (#102)

This test is a nondestructive test. The test validates the correct operation of the

remote access CO trunk used by INADS. The MTP first go es off-hook, then

on-hook on this trunk. If the loop current is detected, the test passes. This test is

not allowed if the remote access line is in use.

PASS The Maintenance/Tape Processor was reset, and it passed initialization
correctly. The other MTP tests should be examined to verify that the MTP is
functioning correctly.
1. Enter test processor a/b and verify that the MTP is functioning
correctly.
Table 10-364. TEST #102 MTP Outpulse Relay Test
Error
Code Test
Result Description/ Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
1018 ABORT The test has been disabled via administration.
1. To enable the test, issue the change system-parameters
maintenance command, and set the test remote access p ort f ield to "y. "
(If you have an INADS line, set the field to "y." If you are testing the
Standby PR-MAINT, a refresh spe-standby command must be
successfully executed before you proceed to Step 2.
2. Rerun the test.
Continued on next page
Table 10-363. TEST #101 MTP Reset Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page