Maintenance Object Repair Procedures
Page10-36ADX16A-PT (AUDIX Analog Line/Control Link)
10
ADX16A-PT (AUDIX Analog Line/Control Link)
!CAUTION:

Never do any of the following without first shutting down AUDIX. Follow the

instructions on the TN566/TN2169 faceplate:
Remove DEFINITY AUDIX circuit packs
Cycle power to a carrier containing DEFINITY AUDIX circuit packs

Remove power to a carrier containing DEFINITY AUDIX circuit packs

The ADX16A-PT maintenance object represents a port on a TN566/TN2169
DEFINITY AUDIX circuit pack that is operating in control-link (CL) mode. For
circuit-pack-level problems (ADX16A-BD or ANL-16-BD), see “XXX-BD
(Common Port Circuit Pack)”. For port-level problems with AUDIX operating in
digital-port mode, see ADXDP-PT/AD X8 D-PT.
The tests described in this section apply only to switch-side maintenance which
tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy that is described in

DEFINITY

AUDIX System Maintenance
, 585-300-110.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction
Board (MFB) and the TN2169 Alarm Board (ALB). Because of its size this
combination occupies 5 slots, but only 1 slot is functional as far as the switch is
concerned. The other 4 slots are seen by the switch as ‘‘AUDIX-reserved’’ slots.
In CL mode the TN566 pack supports up to 16 voice p orts. When a call to a
station with an AUDIX login is not answered, AUDIX answers the call using one of
the available voice ports.
Unlike other AUDIX systems, DEFINITY AUDIX is not an adjunct.
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs).
C
is the carrier designation (A,
B, C, D, or E).
SS
is the number of the slot in which the circuit pack resides (01 to 21).
pp
is the
two digit port number (01, 02, ...).
MO Name (in
Alarm Log) Alarm
Level Initial Command To
Run1Full Name of MO
ADXCL-PT or
ADX16A-PT MINOR test port PCSSpp l AUDIX Analog Line/ Control Link
ADXCL-PT or
ADX16A-PT WARNING test port PCSSpp sh AUDIX Analog Line/ Control Link