Maintenance Object Repair Procedures
Page10-1188STRAT-3 (Stratum 3 Clock)]
10
NOTE:
When looking in the Stratum 3 cabinet, "A " card is on the left an d "B" card is
on the right.
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. In the context of the Stratum 3 clock, an OFF-BOARD alarm occurs when
there is a DS1 facility problem; otherwise, the alarm is ON-BOARD
indicating that there is a fault in the Stratum 3 clock or in the connection
between the Stratum 3 clock and the PBX (Private Branch Exchange)
switch. If the Stratum 3 clock cannot be referenced, and therefore the
local oscillator on the TN780 Tone-Clock circuit pack must serve as the
reference instead, a Major alarm is raised. Otherwise, a Minor alarm is
raised.
b. This error can be caused by one of the following conditions:
1. One or both TOCs (Timing Output Cards) may have failed,
1. Run the Short Test Sequence. Refer to the appropriate test description and f ollo w the recomm ended
procedures.
Stratum 3 Clock Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value
010 Any Any Any test synchronization r 4
1 (d) Any Stratum 3 Clock
Alarm Query (#649) MINOR OFF test synchronization r 4
257 (e) Any Stratum 3 Clock
Alarm Query (#649) MINOR OFF test synchronization r 4
257 (c) None WARNING ON
513 (f) Any Stratum 3 Clock
Alarm Query (#649) MINOR ON test synchronization r 4
769 (g) Any Stratum 3 Clock
Alarm Query (#649) MINOR ON test synchronization r 4
1025 (h) Any Stratum 3 Clock
Alarm Query (#649) MINOR/ MAJOR(a) ON test synchronization r 4
1281 (i) Any Stratum 3 Clock
Alarm Query (#649) MINOR/ MAJOR(a) ON test synchronization r 4
1537 (b) none MINOR/ MAJOR(a) ON