DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-21busyout tone-clock
8
busyout tone-clock
This command places the specified tone/clock in a maintenance busy state. No
periodic or scheduled tests are performed on the busied out object u ntil it is
released. When the object is maintenance busy it is deactivated (no call
processing activity may include the busied object). Warning alarms (error type
18) are generated on each tone clock circuit pack busied out, so that INADS can
determine the state of the objects. The command, release tone-clock,
reactivates the specified tone/clock.
Output
The following example is a display of the busyout tone-clock command.
Field descriptions
Maintenance Name Type of busied out maintenance object: TDM-BUS
Result Test result: Pass, Abort, Fail
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
Action/Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
busyout
tone-clock
location
Physical location (PC)
Examples:
busyout tone-clock 01c
busyout tone-clock 03d
init
inads
craft
1 (one) none
Port Tone/clock board address (cabinet-carrier)
Maintenance Name Circuit pack name: TONE-PT, TDM-CLK, TONE-BD
busyout tone-clock 1a SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01A TONE-PT PASS
01A TDM-CLK PASS
01A TONE-BD PASS
Command successfully completed