DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-731ISDN-SGR (ISDN-PRI Signaling Group)

10
Error Log Entries and Test to Clear Values
Notes:
a. This switch sent a message to the far-end switch or terminal adapter, and the far-end did not respond in the allotted time. Possible causes include link failure and congestion or outage at the far-end. The Aux Data field contains Layer 3 protocol information used by internal counters.If no other symptoms are not present, no action is required. If Layer 3 communication is down, there should be indications in the form of alarms and errors for link components. Check out other errors against ISDN-SGR, ISDN-TRK, and other hardware components on the link.
1. Run the Short or Long Test Sequence. Refer to the appropriate test description and follow the
recommended procedures.
Table 10-241. ISDN-PRI Signaling Group Error Log Entries
Error
Codes Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any test sig-group
<group>
1 (a) Any none
257 (b) Any none test sig-group
<group>
513 (c) Any none test sig-group
<group>
769 Any Primary Signaling
Link Hardware
Check (#636)
test sig-group
<group>
1025 Any Secondary Signaling
Link Hardware
Check (#639)
test sig-group
<group>
1793 (d) Any Layer 2 Status (Test
#647) WARNING OFF test sig-group
<group>
2049 (e) Any Layer 2 Status (Test
#647) WARNING OFF test sig-group
<group>
2305 (f) Any Remote Layer 3
Query (Test #637) MINOR OFF test sig-group
<group>
3585 (g) port
number none none
3840-
3928 (h) port
number none