Maintenance Object Repair Procedures
Page10-1505UDS1-BD (UDS1 Interface Circuit Pack)
10
1039 ABORT The UDS1 Interface circuit pack is providing timing for the system.
Executing this test could cause major system disruption. If the UDS1
Interface circuit pack needs to be tested, set t he s ynchroni za tion refer ence
to another DS1 Interface circuit pack or to the Tone-Clock circuit pack via
the following command sequence:
1. Issue the disable synchronization-switch command.
2. Issue the set synchronizati on PCSS command.
3. Issue the enable synchronization-switch command. Then rerun the
test. If the test aborts again, a different ABORT error code will be
generated. Follow the recommended maintenance procedures fo r that
error code.
1950 ABORT Another loopback/span test is already executing on the DS1 boardor the
board is in a network requested loopback mode (Line loopback or Pay load
loopback). The hardware error log will indicate whether a Customer
Loopback Jack Test, Far CSU Loopback Test, or the One-Way Span Test
is executing or if the board is in line loopback or payload loopback mode.
Only one long-duration loopback/span test can be active at a given time.
Thus, if a loopback/span test is already active, th at tes t mus t be ter minate d
via the
test ds1-loop PCSS end-loopback/span-test
command in order to
execute this test.