DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-279status interface
8
status interface
This command displays the number of counters maintained by the PI. (a front
end processor implementing packet layers and link layers of t he BX.25 protocol
and the integrated services digital network (ISDN) procedure-D protocols.
Cab Assigned cabinet number (1 to the highest system cabinet num ber).
Emerg Trans Settings for emergency transfer switches on the maintenance board for
each cabinet. Available options are: auto-on (“auto+” or “a+” ), auto-off
(“auto-” or “a-”), “on”, “off”, and “n.a.”. The system defaults to “auto+” or
“auto-”. In this state, emergency transfer activate automatically if the
cabinet fails (“+”=emergency transfer is activate, “-” = emerge ncy
transfer is inactive). “on” = emergency transfer automatically activates.
“off” = the cabinet cannot activate emergency transfers. Duplicated
SPEs systems = switch settings for both processors of the PPN (cabinet
1) display. In this case, “auto+” is abbreviated “ a+”, “auto-” is
abbreviated “a-”, and “off” is abbreviated “of”. “on” does not change.
“n.a.” = the emergency transfer switch setting is unavailable.
Mj Number of major alarms associated with the cabinet. Asterisks are used
to fill fields when numbers exceed 99.
Mn Number of minor alarms associated with the cabinet. Asterisks are used
to fill fields when numbers exceed 99.
Wn Number of warnings associated with the cabinet. Asterisks are used to
fill fields when numbers exceed 99.
PNC Port Network Connectivity (PNC) status for each port networks within a
cabinet. When multiple port networks exist, Carriers A, B, and C are
listed first and separated from Carriers D and E by a slash (for example,
up/up). Availability of the Expansion Archangel Link (EAL) determines
PNC status of a port network. “up” denotes that the EAL is a vailable.
“dn” denotes that the EAL is unavailable.
Time of Day Current time of day acquired from the system.
Action/Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
status
interface
location
print
(cabinet-carrier-positio n) of th e
processor interface (PI board). 1 =
the first processor interface in the
carrier; 2 = the second pr ocessor
interface in the carrier.
Report sent to printer.
Examples:
status interface a1
status interface 01a2
status interface 01b1
status interface b2
status interface b2 print
init
inads
craft
cust
rcust
bcms
browse
1 (one) none