DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures
Page10-556DUPINT (Duplication Interface Circuit Pack)
10
Error Log Entries and Test to Clear Values
Notes:
a. This error indicates that an unexpected hardware reset has occurred on
the Duplication Interface circuit pack. Appropriate action has been taken
by the software to prevent malfunction. However, if this type error occurs
with regular frequency, the DUPINT circuit pack may need to be replaced.
b. There are several possible Aux Data fields for this error, including blank.
All indicate loss of contact with the indicated Duplication Interface circuit
packs. The following table summarizes the Aux Data fields.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-185. Duplication Interface Circuit Pack Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test dup 1C sh r 1
1 Sanity Circuit Test (#273) MAJOR/
WRN ON test dup 1C l r 1
108 (a) Any None
109 (a) Any None
257 SAT Loop Back Test (#274) MAJOR/
WRN ON test dup 1C sh r 3
513 SPE A Loop Back Test (#275) MAJOR/
WRN ON test dup 1C sh r 3
769 SPE B Loop Back Test (#276) MAJOR/
WRN ON test dup 1C sh r 3
1025 Sanity Maze Test (#277) MAJOR
/WRN ON test dup 1C sh r 3
1281 (b) Any Dupint Status Query Test (#315) MAJOR/
WRN ON test dup 1C sh r 6
1537 (c) Any Background Test Query Test
(#271) MAJOR/
WRN ON test dup 1C sh r 3
1793 (d) Any MBUS Time-Out Query Test
(#285) MAJOR/
WRN ON test dup 1C l r 3
2049 Inter-Dupint Loop Around Test
(#280) MAJOR/
WRN ON test dup 1C sh r 3