DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-1010PMS-LINK (Property Management System Link)

10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. The PMS Link has been busied out for system techn ician-demanded maintenance via the busyout pms-link command. The link is torn down. Enter the release pms-link command to re store the link.b. The Link Retry Test (#215) fails. The Aux Data field conta ins either the Channel ID of Data Channels on Network Control circuit pack (that is, 3 for Channel 01, 4 for Channel 02, 5 for Channel 03, 6 for Channel 04) or an Error Type of 99 indicating no data channels are available for setting up
1. Run the Short Test Sequence first. If all tests pass, run t he Long Tes t Sequence. Re fer to the appr opriate
test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
3. Is any integer.
PMS Link Maintenance Error Log Entries
Error Type Aux Data Associated Test Alarm Level On/Off
Board Test to Clear Valu e
010 Any Any Any test pms sh r 1
18 (a) 0 busyout pms-link WARNING OFF release pms-link
257 (b) 0-6,
99,
255
Link Retry Test (#215) MINOR/
WARNING2OFF test pms- link l
513 (c) 0-6,255 None test pms-link
769 (d) 0-6,255 None
1025 (e) 4x3None
1281 (f) 1x3None
1537 (g) Nx3None
1793 (h) 0-6,255 None test pms-link
2049 (i) 0-6,255 None
2305 (j) 5x3None release pms-link or
test pms-link
2561 (k) 0-6,255 None test pms-link
2817 (l) 10x3 20x3
30x3None
3073 (m) 7x3None
3841 (n) 2x3None