DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-387test sp-link
8
Feature Intera c tions
Additional data is available after running a test. See the status signaling-group
command for how to access the additional data.
Output
The following output example is for the test signaling-group 1 command. The
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
test sp-link
The test sp-link command validates that the system printer li nk is administered
and runs a series of diagnostic tests that return results of the test along with
possible error codes.
The system printer link is a link from the switch to an external printer over which
jobs can be printed. This link is created by administering the system printer
extension and setting up a call to the system printer.
Port The signaling group number (1-8) of the signaling group th at is
being tested.
Maintenance
Name The type of maintenance object that is being tested.
Alt. Name Not Applicable.
Test No Test being executed
Result Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test signaling-group 1 SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
1 ISDN-SGR 636 PASS
1 ISDN-SGR 639 PASS
1 ISDN-SGR 637 PASS
Command Successfully Completed