DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures
Page10-1448UDS1-BD (UDS1 Interface Circuit Pack)
10
Table 10-489. System Technician-Demanded Tests: Descriptions and Error Codes
Order of Investigation Short Test
Sequence Long Test
Sequence Reset Board
Sequence test ds1-loop
Command D/ND1
NPE Connection Audit
Test (#50) XND
Control Channel Loop Test
(#52) XND
Loss of Signal Alarm
Inquiry Test (#138) XX ND
Blue Alarm Inquiry Test
(#139) XX ND
Red Alarm Inquiry Test
(#140) XX ND
Yellow Alarm Inquiry Test
(#141) XX ND
Major Alarm Inquiry Test
(#142) XX ND
Minor Alarm Inquiry Test
(#143) XX ND
Slip Alarm Inquiry Test
(#144) XX ND
Misframe Alarm Inquiry
Test (#145) XX ND
Translation Update Test
(#146) XX ND
ICSU Status LEDs Test
(#1227) XX ND
SAKI Sanity Test (#53) X D
Internal Loop Around Test
(#135) XD
DS1/CSU Loopback Tests
DS1 Board Loopback Test
(#1209) XD
CSU Equipment Loopback
Test (#1210) XD
CSU Repeater Loopback
Test (#1211) XD
CPE Loopback Jack Test
(#1212) XD
Continued on next page