DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids

Page8-398test tone-clock

8
Output
The responses display on a test-by-test basis with one line of data for each test result. The following is the output for the test tone-clock 1a command.
1. If no alarms are regist ered a gain st the main tena nce o bject the n the t est sequ ence is run only once . The
long clear
option forces a clear of all a larms if no errors are encoun tered during testing. The
short clear
option only clears
alarms pertinent to tests in th e short sequence.
2. Refer to the Report Schedu ler and System Printer feature spec ification for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
test
tone-clock
location
short
long
repeat
number
clear
schedule
PCSS
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestr uctive
diagnostic tests.
How many times each test in the
sequence is repeated (1- 100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequenc e fails.1
Command is validated and th en a
scheduling form displays to
schedule execution of th e
command. The command is then
placed in the command queue an d
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.2
Examples:
test tone-clock 01a l
test tone-clock 01b l schedule
init
inads
craft
Test
Sequence
= short;
Repeat =
1
none