DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures
Page10-1227SYS-PRNT (System Printer)
10
3. 4- time-out during se tup attempt. Most lik ely due to problem wit h
physical link or printer status.
4. internal system error. Most likely temporary/sporadic failure.
5. the data module the printer is trying to use is busy with another call.
Use the Status data module command to determine when the port
is available for testing.
Refer to the ‘‘Procedures for Restoring the System Printer Link’’ section for
recommended maintenance strategy.
c. The SYS-PRNT was interrupted because of one of the following reasons:
1. the cable to the SYS-PRNT output device is disconnected;
2. the SYS-PRNT output device is powered off;
3. the data extension to which the SYS-PRNT output device connects
has been busied out;
4. internal software error.
Check the connectivity of the wires and cables among the wall jacket,
data module, and SYS-PRNT output device. Follow the instructions
provided in the ‘‘Procedures for Restoring the System Printer Link’’
section.
System Technician-Demanded Tests:
Descriptions and Error Codes
When inspecting errors in the system and deciding which ones to address,
always investigate errors in the order they are presented in the table below. By
clearing error codes associated with the
Link Retry Test
, for example, you may
also clear errors generated from other tests in the testing sequence.
1. D = Destructive; ND = Nondestructive
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
Link Tear Down Test (#213) X D
Link Retry Test (#215) X X ND
Link Tear Down Test (#213) X X ND