DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-75display synchro nization
8
Field descriptions
Stratum: Synchronization stratum that is used (3 or 4)
Primary: First choice system synchronization source (blank = no
synchronization); valid only if stratum 4 synchronization specified
Secondary: Second choice system synchronization source (blank = no
synchronization); valid only if stratum 4 synchronization specified
Location: Circuit pack location (cabinet-carrier-slot) of all administered DS1 circuit
packs are listed here.
Name: User-defined name administered for the DS1 circuit pack. Blank means
no user-defined name administered.
Slip: If the DS1 circuit pack has slip alarm, field shows y; otherwise it shows
n.
Port
Network: Only valid for stratum 3 synchronization; specifies the port network
supplying synchronization through the tone clock circuit pack.
display synchronization Page 1 of 2
SYNCHRONIZATION SOURCE (DS1 circuit pack location)
Stratum: 4
Primary: Secondary:
DS1 CIRCUIT PACKS
Location Name Slip Location Name Slip
02B10 D92D1 ds1 2b10 n
02B11 d92D1 ds1 2b11 n
01C10 D92D1 ds1 1c10 n
01C11 D92D1 ds1 1c11 n
NOTE: TN722B DS1 sources result in stratum 4, type II synchronization
display synchronization Page 2 of 2
SYNCHRONIZATION PLAN
DS1 CIRCUIT PACKS
Location Name Slip Location Name Slip