DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-275status hardware-group
8
Field descriptions
status hardware-group
Summary information for the active or last hardware group test displays. Th is
display includes the number and percentage of tested maintenance objects, the
percentage of tests passed, failed, and aborted, the time el apsed since initiating
the hardware group test, the specific hardware group test command (see ‘‘test
hardware-group’’ command) initiated, and the state (active/canceled/complete)
of the hardware-group test.
Data Ext/Sta Ext
for Stn DM The data module extension number. The DTDM is an exception: the
connected station extension is shown.
Port/Channel
Number The port location of the data module (cabinet-carrier-slot-circuit). If
the data module specified is a data channel, the channel number is
shown instead.
Service State This entry displays the status of the data module; valid states are:
— In-service/idle
The data module is present but not in u se.
— In-service/active
The data module is present and is in use.
—Out-of-service
The data module has been removed from service
— Disconnected
The data module no longer appears to b e present
CF Destination Ext This entry displays the call forwarding destination, if any, of the
station.
Maintenance Busy? Wheth er maintenance is testing the object, "yes" or "no".
Connected Ports Port locations to which the data module is connected
(cabinet-carrier-slot-circuit).
Action/Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
status
hardware-group
print
Report sent to printer.
Examples:
status hardware-group
status hardware-group print
init
inads
craft
cust
rcust
bcms
browse
none none