DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures
Page10-45ANL-16-L (16-Port Neon Analog Line)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates
that no terminal equipment was present when ringing was attempted.
Execute the short test port PCSSpp command, and follow the procedure
for the results of Test #48.
40960indicates that too many simultaneous incoming ringing
attempts were ma de on this board. Only four ports on a board may
be ringing simultaneously. A fifth incoming call will cause an inline
error from the board.
1. Run the Short Test Sequence first. If all tes ts pas s, r un t he Long Tes t Seque nce. Refer t o the appropr i ate t est
description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded t o Warni ng alarms based o n the val ues used i n the set options
command.
Table 10-19. 16-Port Neon Analog Line Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value
010 Any Any Any test port PCSSpp sh r 1
1 (a) 40960
40977 none
15 (b) Any Audits and Updates
Test (#36)
18 0 busyout station
<extension> WRN ON release station <extension>
130 (c) None WRN ON test port PCSSpp sh
257 (d) 40973 none
513 (e) Station Present Test
(#48) WRN OFF test port PCSSpp sh r 2
769 Battery Feed Test
(#35) MIN/WRN2ON test port PCSSpp sh r 2
1025 Loop Around Test
(#161) MIN/WRN2ON test port PCSSpp l r 2
1281 Conference Test (#7) MIN/WRN2ON test port PCSSpp l r 2
1537 NPE Crosstalk Test
(#6) MIN/WRN2ON test port PCSSpp l r 2