DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-303CO-TRK (CO Trunk)

10
3. PBX On-Hook first (Drop Message): Open the Tip-Ring Loop, no loop currenta. CO Response: Open circuit on Tip4. CO On-Hook first (Disconnect): Open circuit on Tip, no loop current
Hardware Error Log Entries and Test to Clear
Values
Table 10-99. CO Trunk Error Log Entries
Error Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Cl ear Value
010 Any Any Any test port PCSSpp sh r 1
1 (a) 57347 None
15 (b) any Port Audit Update
Test (#36)
18 0 busyout trunk
<grp>/<mbr> WARNING OFF release trunk
<grp>/<mbr>
130(c) None WARNING ON test trunk <grp>/<mbr>
257 (a) 50176 None
513 (a) 57364 None MAJ/MIN/
WRN2ON
769 (a) 57392 None MAJ/MIN/
WRN2OFF
1025 (e) Any Demand Diagnostic
Test (#3) MAJ/MIN/
WRN2OFF test port PCSS sh r 2
1281 (e) Any Demand Diagnostic
Test (#3) MAJ/MIN/
WRN2ON test port PCSS sh r 3
1537 Dial Tone Test (#0) M AJ/MIN/
WRN2OFF test port PCSS l r 2
1793 Loop Around and
Conference Test
(#33)
MAJ/MIN/
WRN2ON test port PCSS l r 3
2049 NPE Cross Talk Test
(#6) MAJ/MIN/
WRN2ON test port PCSS l r 3
2561 (d) 57345 None
2817 (a) 57360 None
2817 (a) 57393 None
Continued on next page