Maintenance Commands and Trouble-Clearing Aids
Page8-367test modem-pool
8
1. If no alarms are registe red against the maintenanc e object then the test seq uence is run only once. T he
long
clear
option forces a clear of all al arms if no errors are encounter ed during testing. The
short clear
option only
clears alarms pertinent to test s in the short sequence. SEE WA RNING BELOW
2. Refer to the Report Scheduler an d System Printer feature specifi cation for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
test
modem-pool group
number
member
number
short
long
repeat
number
clear
schedule
The administered group nu mber
(1-5)
The administered member
number (1-32). A member is a pair
of analog and digital line por ts (two
pair for the Integrated
modem-pool).
Option for a brief seri es of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of bo th
destructive and nondestructive
diagnostic tests.
Number of times each te st in the
sequence is repeated (1-1 00)
This option causes the test
sequence (short or long) to repea t
until the alarm (if any) is clear ed or
a single test in the sequ ence fails.1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is th en
placed in the command qu eue and
is executed at the specified time.
The information displayed by the
command is sent to the syst em
printer instead of the sc reen.2
Examples:
test modem-pool 1
test modem-pool 1 schedule
test modem-pool 1/3 l r 2
test modem-pool 1/3 l r 2
schedule
test modem-pool 2 r 2
test modem-pool 2 l
init
inads
craft
Test
Sequence
= short;
repeat = 1
none