DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-147BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack)

10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This error indicates the circuit pack totally stopped functioning or it was physically removed from the system.
1. Run the Short Test Sequence first. If all t ests pass, run the Long Test S equence. Ref er to t he appropr iate
test description and follow the recommended procedures.
Table 10-53. BRI-BD Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test board PCSS sh r 1
1(a) Any None MINOR ON
18(b) 0 busyout board
PCSS WARNING OFF release board PCSS
23(c) 0 None WARNING OFF
257(d) 65535 Control Channel
Loop Test (#52) MINOR ON test board PCSS r 20
513(e) 4352 to
4357
769(f) 4358
1025(g) 4363 NPE Audit Test
(#50)
1293
to
1294 (h)
46088
to
46096
SAKI Sanity Test
(#534) MINOR ON See footnote (h)
1537 to
1538 (i) 46082 MINOR ON
1793 (j) 46080 MINOR ON
1794 (j) 46094 MINOR ON
1795 (j) 46085 MINOR ON
2306 (j) LANBIC Receive
Parity Error Counter
Test (#595)
3330 (k) 46083 MINOR OFF
3840 (l) 4096 to
4101
3843 (m) 46097
3999 (n) Any None
Continued on next page