DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-18busyout spe-standby
8
the STBY-SPE Warning alarm are maintained across a reset system 1 (Warm
restart) and a reset system 2 (Cold 2 restart) but are removed after all other levels
of restart.
Feature Intera c tions
■When a busyout of the standby SPE is performed, the fault severity level of
the standby SPE is set to the highest possible value and memory
shadowing is turned off. T his is done to lessen the probability that the
system switches to the standby SPE. However, in some cases a
“spontaneous” (hard) interchange of the SPEs may still occur.
■This command can be used as a mechanism to turn off memory
shadowing of the standby SPE.
■If the standby SPE is in poor health (less than optimum), memory
shadowing can not be disabled, or communication to the standby is
impossible a busyout of the standby SPE are still successful.
Output
The following example is a display of the busyout spe-standby command.
Field descriptions
Action/Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
busyout spe-standby Examples:
busyout
spe-standby
init
inads
craft
none See below
Port Standby SPE cabinet and carrier location (01A or 01B)
Maintenance Name Always STBY-SPE
Alt. Name Always blank
Result Test result: Pass, Abort, Fail
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
busyout spe-standby SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01B STBY-SPE PASS
Command successfully completed