DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-676HYB-LINE (Hybrid Line)

10
When the status station command has been run, and the status screen appears, the status is reported as either out-of-service or in-service, which mean exactly as stated in the above list, or disconnect, which m eans the station is in the ready-for-service state.
Hardware Error Log Entries and Test to Clear
Values
Notes:
1. Run the Short Test Sequence first. If all t ests pass, run the Long Test S equence. Ref er to t he appropr iate
test description and follow the recommended procedures.
2. Major or Minor alarms on this MO may be downgraded to Warning alarms based on the va lues used i n
the set options command.
Table 10-224. Hybrid Line Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test port PCSSpp sh r 1
1 (a) Any None WARNING OFF
15 (b) Any Hybrid Audits Test
(#61)
18 (c) 0 busyout port
PCSSpp WARNING OFF release port PCSSpp
130 (d) None WARNING ON test port PCSSpp sh
257 (e) 40988 None MIN/WRN2OFF
513 (f) 40965 Hybrid Line Audits
Test (#61) WARNING OFF test port PCSSpp sh r 4
769 (g) Remote Dig Loop
Around Test (#59) WARNING OFF test port PCSSpp sh r 3
1025 Hybrid & Conf.
Circuits Test (#57) MIN/WRN2ON test port PCSSpp l r 3
1281 (h) Local Digital Loop
Around Test (#58) WARNING ON test port PCSSpp l r 3
1537 (i) 40968 None WARNING OFF
1793 TDMNPE Crosstalk
Test (#6) MIN/WRN2ON test port PCSSpp l r 3
2049 (j) 32770 None
2049 (k) 40967 None
Continued on next page