DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page8-44disable test-number
8
disable test-number
This command prohibits selected maintenance tests from running. To run a
disabled test number, enter the enable test-number command.
display alarms
This command creates an Alarm Report. The user completes an option screen to
select the parameters for the report.
The system creates the reports from the logs of the maintenance subsystem. The
subsystem monitors the system hardware and logs problems as errors or alarms.
The type of alarm indicates the impact of the problem, as defined below:
Warning alarmA minor interference which does not noticeably impai r service.
Minor alarmA problem which could disable a local area of the system and
noticeably impair service.
Major alarmA problem which widely degrades the system and seriously
impairs service. The system automatically calls INADS to report major alarms.
Resolved alarmA problem which has been corrected, and the system i s
correctly functioning. The system stamps resolved alarms with the date and time
the problem was corrected. The system handles any errors associated with the
alarms as “resolved.”
1. Refer to the Report Scheduler an d System Printer feature specifi cation for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
disable
test-number
number
print
schedule
Maintenance test number
Report sent to printer
Command is validated and then a
scheduling form displays to
schedule execution of th e
command. The command is then
placed in the command queu e
and is executed at the spec ified
time. The information displayed
by the command is sent to the
system printer instead of the
screen.1
Examples:
disable test-number 710
disable test-number 710 print
disable test-number 510
schedule
init
inads none none