DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids

Page8-390test spe-standby

8
Feature Intera c tions
Testing the standby SPE maintenance object makes the standby SPE unavailable to take over for the active SPE.
Output
The following output example for the test spe-standby command assumes that the standby SPE is located in carrier B. The responses display on a test-by-test basis with one line of data for each test result.
1. If no alarms are registered agains t the maintenance object then the test s equence is run only once. The
long clear
option forces a clear of al l alarms if no errors are en countered during testing. The
short clear
option only clears
alarms pertinent to tests in th e short sequence.
Action/Object Qualifiers Qualifier Description Permissions Defaults Feature
Interactions
test
spe-standby short
long
repeat
number
clear
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestr uctive
diagnostic tests.
How many times each test in the
sequence is repeated (1- 100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequenc e fails.1
Examples:
test spe-standby long
test spe-standby l
test spe-standby s r 2
test spe-standby c
init
inads
craft
Test
Sequence
= short;
Repeat = 1
See below