DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Reliability Systems: A Maintenance Aid

Page6-30Repair Procedures for High and Critical Reliability

6
Figure 6-3. Page 3 Procedure for Replacing Standby SPE Circuit Packs
Installnew circuit
pack
Insertsoftware
memory card into the
activeSPE. Usethe
"listconfigsoft"
command to verify
youhave thecorrect
version. Ifthe
softwaredoes not
matchor the update
filecontains data
escalate.
Replacethe
translationmemory
card in the active
SPE
Issuethe "test"
commands on the
NEW circu it pack to
resolve alarms
If" list" or "tes t"
commands are
blockedafter
repeatedtries, use
the"busyout
spe-standby"and
"releasespe-standby"
commands and try
again
Replaceprocessor
circuitpack (do not
removeSPE power)
Replacesoftware
memorycardwith
translationmemory
cardwhen prompted
from SAT
IGNORE prompt from
SATtoreplaceactive
translationmemory
card.Wait 3 minutes.
"listconfiguration
software-versions
long"to verify
identicalactiveand
standbysoftware
Installnew circuit
pack
Re-insertthe standby
SPE processorcircuit
pack
Insertsoftware
memory card into
standbySPE
Waitfor background
SPEtestingtofinish
"status sys tem 1"
Throwthe SPE select
switches to the
normalposition, one
ata time
Are
thereother
defectivecircuit
packsto be
replaced?

DC

E

B

E

YES
NO