Maintenance Commands and Trouble-Clearing Aids
Page8-335test data-module
8
!WARNING:
Since the “clear long” options clear all counters if tests pass, it is possible
for firmware counters to be cleared even when a problem exists. I n some
cases customer service might degrade since calls may be routed over
defective equipment.
1. If no alarms are registe red against the maintenanc e object then the test seq uence is run only once. T he
long
clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only
clears alarms pertinent to test s in the short sequence. SEE WA RNING BELOW.
2. Refer to the Report Scheduler an d System Printer feature specifi cation for more details.
Action/
Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
test
data-module
extension
short
long
repeat
number
clear
schedule
Extension of the data module o r
data channel to be tested (per
dial-plan)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive test se ries
(includes a destructive tes t)
How many times each test in the
sequence is repeated (1-1 00)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.1
Command is validated and the n a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue a nd
is executed at the specifi ed time.
The information displayed by the
command is sent to the system
printer instead of the scree n.2
Examples:
test data-module 30000 l
test data-module 30000
test data-module 32000 sh r 2
test data-module 33000 l r 25
test data-module 33000 l r 25
schedule
test data-module 30000 c
init
inads
craft
cust
nms
Test
sequence
= short;
repeat = 1
none