Maintenance Commands and Trouble-Clearing Aids

Page8-339test duplication-interface

8
DUPINT is associated with the duplication interface circuit packs other
functions, including SPE-to-SPE communication, SAT connection, and environmental maintenance leads.
1. If no alarms are registered agai nst the maintenance object the n the test sequence is run only once . The
long clear
option forces a clear of al l alarms if no errors are en countered during testing. Th e
short clear
option only clears
alarms pertinent to tests in th e short sequence.
2. Refer to the Report Scheduler an d System Printer feature specifica tion for more details.
Action/
Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
test
duplication-
interface
location
short
long
repeat
number
clear
schedule
SPE location of the duplicatio n
interface circuit pack (1a, 1b , a, or
b)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive test series
(includes a destructive test)
How many times each test in the
sequence is repeated (1- 100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequenc e fails.1
Command is validated and th en a
scheduling form displays to
schedule execution of th e
command. The command is then
placed in the command queue an d
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.2
Examples:
test duplication-interface a
test duplication-interface b sh
test duplication-interface a l r 25
test duplication-interface 1b l r
25 schedule
test duplication-interface 1a l c
init
inads
craft
Text
sequence
= short;
repeat = 1
Duplication-
interface
failures may
prevent SPE
switching.