DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures
Page10-1240TAPE (Tape Unit) [G3iV1.1-286]
10
n. [G1.1 and earlier] If these errors occur in conjunction with Error Type
#3329, a major alarm is logged against the error type. To resolve this
alarm, follow the instructions for Error Type #3329.
o. [G1.1 and earlier] "Leaky Bucket" strategy for Error Types #1793, #1828,
#2049, #2051, and #2084 on the Active SPE. Whenever any of these
errors appear in the Error Log, they will be automatically resolved within 48
hours if the errors do not recur within that period. In G1.0, this is the only
way these errors can be cleared (without resetting the system).
System Technician Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
Tape DMA Latch Test
for example, you may also clear errors generated from other
tests in the testing sequence.
Notes:
a. The Tape Read/Write Test only runs in the following software releases;
G1
G3iV1, EDI 6.0 and earlier.
b. The Tape Block Error Test runs only in software release G3iV1, EDI 15.0
and earlier.
c. Refer to TAPE-DAT (Tape Consistency) Maintenance documentation for
the description of this test.
1. D = Destructive; ND = Nondestructive
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
Tape Reset Test (#67) X ND
Tape DMA Latch Test (#230) X X ND
Tape Diagnostic Test (#66) X X ND
Tape Read/Write Test (#65) (a) X ND
Tape Block Error Test (#692) (b) X ND
Tape Status Test (#69) X X ND
Tape Translation Status Test (#505) X ND
TAPE-DAT Tape Consistency Test (#421) (c) X ND