DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids

Page8-386test signaling-group

8
test signaling-grou p

This command validates that the specified signaling group is administered and

runs a series of diagnostic tests that return results of the test along with possible

error codes. A signaling group is a collection of B-channels signaled for by a

designated single D-channel or set of D-channels over an ISDN-PRI.

!WARNING:
Since the “clear long” options clear all counters if tests pass, it is possible
for firmware counters to be cleared even when a problem exists. I n some
cases customer service might degrade since calls may be routed over
defective equipment.
1. If no alarms are registered agains t the maintenance object then the test sequence is run only once. The
long clear
option forces a clear of al l alarms if no errors are encountered during testing. The
short clear
option only clears
alarms pertinent to tests in th e short sequence. SEE WARNING B ELOW.
2. Refer to the Report Scheduler an d System Printer feature specifi cation for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
test
signaling-group group
identifier
short
long
repeat
number
clear
schedule
The station extension (must
conform to dial-plan)
Option for a brief series o f
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-10 0)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequen ce fails.1
Command is validated and the n a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specifie d time.
The information displayed by th e
command is sent to the sys tem
printer instead of the s creen.2
Examples:
test signaling-group 1
test signaling-group 1 repeat 10
test signaling-group 2 short
test signaling-group 4 long
test signaling-group 4 long clear
test signaling-group 2 schedule
init
inads
craft
Test
Sequence
= short;
Repeat =
1
See below